The ART-3D series are precision instruments, designed to measure turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076.

The instrument’s rugged design is perfectly suited to tackle the most challenging field or manufacturing environments. The anti-induction mode strongly enhances the efficiency of the measurements by countering the unwanted effect of nearby induction interference. The large, high contrast, color, touch screen display offers easy menu navigation, creation of test plans and viewing of test files. The integrated LTC control terminal allows for manual or fully automatic testing sequence of On-Load Tap changers with configurable pulse duration and duty cycle. The additional tertiary winding channel of the ART-3Dx will save a great deal of time, with onetime test connections to primary, secondary and tertiary windings. One of the ART-3D’s key features is the colored and graphical way of displaying LTC test results for interpretation in seconds!

With its real 3-phase test circuit, the ART-3D can address complex ratio measurements of PhaseShifting/Regulating or irregular vector group type transformers, otherwise impossible to achieve with conventional ratio meters. Zigzag type transformers testing is very easy and will not require the installation of jumpers or the use of relay matrix circuits. The single or real 3 phase voltage output up to 275V contributes to higher magnetization currents and therefore stronger flux for better signal reflection on secondary and/or tertiary windings allowing more accurate results. The ART-3D phase displacement measurements enables for simple detection of the transformer vector group.

If any question about your NDB ART-3D instrument problem, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Utara, Indonesia
Phone : +62-21-29541370
Fax : +62-21-29541370
Email : adi.wahyu@dynamicscircuit.com
Office Hour : Monday to Friday, 08.00am to 05.00pm



Sunday, November 29, 2015

The Single-phase TTR® Transformer Turns Ratio Test Set measures the turns ratio and exciting current of windings in power, potential and current transformers. Deviations in turns ratio readings indicate problems in one or both windings or the magnetic core circuit.

The TTR test set aids in identifying:
 - Shorted coils
 - Open circuits
 - Incorrect connections
 - Internal faults or tap-changer defects in step regulators as well as in transformers.

The single-phase, hand-cranked model measures highly sensitive turns ratios of up to 129.99:1 with accuracy of ±0.1%. An optional auxilary transformer extends the ratio range to 329.99:1.

The TTR set operates on the principle that the voltage ratio of the transformer at no load is practically equal to the true turns ratio.

The major source of error in a transformer is a primary impedance drop due to magnetizing current, which is kept to a minimum by excitation at a fraction of rated voltage. By employing a design that meets both of these conditions along with the use of a null balance system, the turns ratio of a transformer can be determined accurately.

When measuring the turns ratio of distribution and power transformers, the accuracy is well within 0.1%.

If any question about your instrument problem, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Utara, Indonesia
Phone : +62-21-29541370
Fax : +62-21-29541370
Email : adi.wahyu@dynamicscircuit.com
Office Hour : Monday to Friday, 08.00am to 05.00pm


The OTS60AF/2, OTS80AF/2 and OTS100AF/2 are used for determining the dielectric strength of liquid insulants, such as the insulating oils used in transformers, switchgear and other electrical apparatus.

The test sets are fully automatic. The operator has simply to prepare the test vessel, load it with sample oil, place it in the test chamber, select the appropriate specification for the tests and then start the test sequence. The test set carries out automatically (and if necessary unattended) the sequence of tests as defined by the pre-selected national specification.

The OTS80AF/2 has gone obsolete. You still have OTS80AF/2 and do not know where to service or repair? 

Please contact us:

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Utara, Indonesia
Phone : +62-21-29541370
Fax : +62-21-29541370
Email : adi.wahyu@dynamicscircuit.com
Office Hour : Monday to Friday, 08.00am to 05.00pm



The TM1800™ is the instrument platform for circuit breaker maintenance, based on more than 20 years’ experience of over 4,000 delivered breaker analyzers. The modular construction makes it possible to configure the TM1800 for measurements on all known types of circuit breakers in operation on the world market.

The robust design contains powerful technology that streamlines circuit breaker testing. Sophisticated measurement modules enable great time savings as many parameters can be measured simultaneously, eliminating the need for new setup each time.

The patented DualGround™ testing using the DCM module makes the testing safe and time saving by keeping the circuit breaker grounded on both sides throughout the test. The DCM module uses a measuring technology called Dynamic Capacitive Measurement. 

Timing M/R is using the patented Active Interference Suppression to obtain correct timing and accurate PIR (Pre-Insertion Resistor) values in high voltage substations.

An adaptive, easy-to-use software suite supports activities from timing, simply turning a knob without the need for presetting, to advanced help functions for hooking up to the test object. A full keyboard and 8” color screen is the front end of the high-level user interface. The Select-Connect-Inspect workflow guides you to fast results in three steps. Testing is made easier to learn and perform.

The system also offers full connection capability to the local network, printers etc.

If any question about your instrument problem, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Utara, Indonesia
Phone : +62-21-29541370
Fax : +62-21-29541370
Email : adi.wahyu@dynamicscircuit.com
Office Hour : Monday to Friday, 08.00am to 05.00pm



Friday, November 27, 2015

The FREJA™300 relay testing system is a computer-aided relay testing and simulation system. The rugged hardware design is built for field use over a wide temperature range, with the possibilities of intelligent software to perform rapid testing.

The very accurate (typically 0.01%) low level analogue inputs are designed for transducer measurements. The high level inputs can be used as a normal volt- and ammeter. FREJA 300 can generate 4x150 V (82 VA) and 3x15 A (87 VA) or 1x45 A (250 VA). Each output can be varied independently. Both static and dynamic testing can be performed, such as prefault and fault generation, simultaneous ramping of several quantities and wave form editing.

FREJA 300 can also be used as a disturbance simulator and create and generate simulated disturbances, or import actual recorded disturbances from e.g. EMTP or COMTRADE files.

If any question about your instrument problem, don't hesistate to contact us :


PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com


10 kV insulation resistance testers from Megger are designed specifically to assist you with the testing and maintenance of high voltage electrical equipment. IEEE 43-2000 recommends the use of 10 kV for motor windings rated above 12 kV and the Megger S1-1052/2 facilitates this.

The instruments have a large easy to read backlit LCD display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly, removing the need for separate timers. Adjustable timers and limit alarms are included. 

The S1-1052/2 are equally suited to routine testing and diagnostic regimes being pre-programmed with IR, PI, DAR, SV and DD profiles.

If any problem about your instruments, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com



The DUCTER DLRO 10 and DUCTER DLRO 10X make up a family of low resistance ohmmeters that measure resistances in the range from 0.1 µΩ to 2 kΩ. Both instruments provide a maximum test current of 10 Amps d.c. which is automatically selected according to the value of resistance being tested. The DLRO 10X allows you to override this automatic selection and sele...ct your own test current.

The measured value of resistance is output to the instrument display with indication of the units, µΩ, mΩ or Ω. The DLRO 10 uses a large LED display and indicators to display the value and units respectively, while the DLRO 10X contains all the information on a clear backlit LCD display.

The use of a four terminal measurement technique removes the test lead resistance from the measured value and auto current reversal eliminates the effect of standing voltages across the test sample. 

Additionally, before and during a test, test lead contact is monitored to further reduce the chance of erroneous readings.

If any question about DLRO 10X problem, don't hesistate to contact us:

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com

PT. Dynamics Circuit Indonesia is qualified and designated as an Authorized ISA Service Center to perform maintenance services on DRTS6 - CBA1000 - DRTS66 - T1000 & T3000 - STS5000 & TD5000.

ISA is a leading-edge worldwide manufacturer of Advanced Test and Measurement Systems whose MISSION IS TO PROVIDE HIGHEND TEST SETS to electrical utilities, power equipment manufacturers, industry and electrical testing and service companies.

ISA headquarter is based in the new premise in Taino, Northern Italy, and regional offices are based in Singapore and New Delhi, India. ISA distributor network with more than 100 representatives cover more than 80 countries all over the world.

ISA is a leading worldwide provider of Advanced Test and Measurement System to such diversified industries as: 
 - Electrical Utilities
 - Power equipment manufacturers 
 - Petrochemical & Chemical Industry 
 - Heavy Industry 
 - Contractors and Engineering 
 - Electrical Testing Service Companies

If any question about ISA instrument problem, don't hesistate to contact us:

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com



Tuesday, November 24, 2015


Insulation Resistance Tester - Megger BM25 has gone obsolete. You still have Megger BM25 and do not know where to service or repair?
 Please contact us:

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com



We are authorized service center for Megger products in Indonesia. we have original Megger calibrator for your Megger product. The CAL4000 is designed for use in performing calibration adjustments of the DELTA4000 series of instruments. Together with provided software, it allows for proper adjustment of critical measurements within the DELTA4000 including: tan delta (PF), capacitance, voltage, current, watts and other measurements.

If any questions about your Megger DELTA4000, don't hesistate to contact us:

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com



PT. Dynamics Circuit Indonesia rental programs are designed for value-conscious companies looking to avoid the costs of owning, repairing and calibrating portions or entire labs of their test and measurement equipment. We are lets customers rent with flexible terms that remove risk while eliminating the need for capital expenditures.

Option of equipment that you can rent are :
 1. DC Insulation Resistance Tester (1kV / 5 kV / 10 kV)
 2. Digital Low Resistance Ohmmeter (DLRO) / Microohmmeter ( 200 A)
 3. Circuit Breaker Analyzer
 4. Single Phase Relay Tester
 5. Single Phase Transformer Turn Ratio Tester

If any questions about electrical test instrument rental, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com



Sunday, November 22, 2015

FADOS7F1 Trouble Shooting and Osciloscope Device is designed for trouble shooting all types of electronic boards. The FADOS7F1 is a PC-Based VI Test Voltage - Current Analysis device.
Signature Analysis is a power-off test method that is used to troubleshoot circuit boards. FADOS7F1 works by applying a current-limited sine wave through a serial resistor point of touched on circuit and Voltage-Current (Signature) graph is displayed on the computer screen.
In addition to these features, the computer software analyzes the Voltage – Current graph and shows the equivalent circuit diagram and the electronic components of the contact point. Those futures are intended to provide guidance to the user in order to facilitate trouble shooting.
Using the Dual Channel VI test feature, the intact and defective (or suspect) electronic boards can be compared by touching the same points on each board at the same time, thus the out-oftolerance malfunctions can easily be diagnosed with this method. All the VI graphs are produced by the software making analyses at 720 separate points with an accuracy of 2.5 mV. Therefore the FADOS7F1 is very accurate.
Memory Recording feature; by means of this feature, the characteristics of the intact electronic board ( VI graph, equivalent circuit diagram and electronic components values) are written on the computer’s hard disk and taking these points as reference, you can compare the defective (or assumed to be defective) electronic boards accurately, easily and rapidly. At the same time, the data can be written on the photograph of the board. Thus, the recorded point can be seen on the photograph while making a comparison from the memory.
The software produces different sounds while comparing the matching and non-matching points during the test, thus allowing to concentrate only on the sound for a rapid comparison without having to look at a board or display continuously. The user can compare the electronic boards from 3 different settings at the same time. (Selected Current-Voltage-Frequency steps)
In addition to the above features, the VI FADOS7F1 Test Device can be used as a Dual-channel Oscilloscope, Square Wave Generator and Analog Voltage output. When the Square Wave Signal Output is used, a signal is applied to the electronic board and the other channels display the output signals on the oscilloscope screen.
Technicians, engineers and hobbyists have found VI graph to be an effective and efficient method for troubleshooting printed circuit boards. The signature comparison method is easy to use and allows for immediate feedback that will assist you in locating faulty component. As you gain some experience with VI graph you will realize that FADOS7F1 is an indispensable troubleshooting tool. Usage is very easy and users will find the faults just by looking at graphs without comparison.
When test Printed Circuit Assembly (PCA) with FADOS7F1, do not apply power to PCA. PCA and the devices must be made high-voltage capacitor discharges. There is no risk of further damage to the PCA while testing and troubleshooting.
FADOS7F1 is easy to carry since it’s small. It can be carried in a laptop briefcase. Including many more features, it is like a Swiss knife of users dealing with electronics.

If any question about ProT Ar-Ge FADOS7F1, don't hesistate to contact us :
PT. Dynamics Circuit Indonesia
Jl. P. Tubagus Angke No. 10 Blok C11
Komplek Jelambar Center
Grogol-Petamburan
Jakarta Barat - 11460
Indonesia
Phone & Fax : +62-21-29541370
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com

Hioki insulation resistance testers or megohmmeters feature all-in-one designs including built-in rugged cases and test lead storage compartments. The 3455 is a 5-range, 250V to 5000V digital insulation resistance tester with bargraph, built-in memory, leak current and voltage testing, and DAR and PI calculation capabilities to help shorten wo...rk time associated with field insulation testing.


If any questions about HIOKI 3455 problems, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6604013
Email : indoservice@dynamicscircuit.com


Thursday, November 19, 2015

Megger DELTA4000 series is a fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters, and rotating machinery.


The test set is designed to provide a comprehensive AC insulation diagnostic test. The high power variable frequency design generates its own test signal independent of line frequency quality and the hardware design uses the latest technology available for digital filtering of the response signal. As a result, the DELTA4000 Series produces reliable results and stable readings in the shortest time with the highest accuracy, even in high interference substations.


If any questions about Megger Delta 4000, don't hesistate to contact us :


PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6604013
Email : indoservice@dynamicscircuit.com
The CARINA fire detection panel is a conventional type product intended to prevent any risk linked to fire activating aboard your vessel. This equipment as well as all the detectors and associated accesories are approved by the main maritime classificaiton companies.

If any questions about fire alarm detection system problems, don't hesistate to contact us :


PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com

Tuesday, November 17, 2015

The BIDDLE PFL-6000 Constant Energy Power Fault Locator is designed to locate cable faults on cable rated up to 32 kV ac phase-to-phase. This integrated system includes an arc reflection filter, surge generator, high potential tester, cable burner and DART Analysis System in a single chassis.

If any question about PFL-6000 problems, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com


The Megger OTS100AF Automatic Laboratory Insulating Oil Tester is the latest in oil test design and has replaced the Megger OTS100AF/2. This new oil test set is able to perform accurate breakdown voltage tests on mineral, ester and silicon insulating liquids. The OTS100AF offers repeatable results with lock-in precision, electrode gap adjustment. The transparent, shielded lid and large test chamber enable easy access to the test vessel. One of the fundamental tests of oil quality is the breakdown voltage test, which is a measure of the oil's ability to withstand electric stress. A low breakdown voltage can indicate the presence of contaminants such as water or conducting particles. The test voltage of the OTS 100AF is electronically controlled to the maximum of 100 kV and it has been designed to perform breakdown detection in terms of both voltage and current, which helps the range to comply with any future changes or developments in oil test standards.

If any question about Megger OTS100AF, don't hesistate to contact us :


PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com
The microohmeter PME-100 is used to measure accurately the contact resistances of switches, circuits breakers, motor and transformers windings and others. The measurement is performed through the current evaluation and the voltage drop on the unknown resistance, with 4 wires to prevent against the influence of contact and cable resistances. The result is internally converted by a highly accurate and stable ele...ctronic circuit and is sent to the 3 1/2 digit liquid crystal display, allowing a direct reading in Ohms, milliOhms or microOhms, according to the selected scale.
Easy to use, ideal for field, laboratory, and production line applications.

If any questions about SMC PME-100 problems, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & fax : +62-21-6604013
Email : indoservice@dynamicscircuit.com


Battery in power plants and transformer substantions must provide the equipment they serve with standby power in the event of power failure. Unfortunately, however, the capacity of such batteries can drop significantly for a number of reasons before thei calculated life expectancy at regular intervals, and the only reliable way of measuring battery capacity is to conduct a discharge test.

Torkel 840 is used for battery systems ranging from 12 to 250 V - often encountered is switchgear and similar equipment. Discharging can take place at up to 110 A, and if higher current is needed, two or more torkel 840 units or extra load units, TXL, can be linked together. Tests can ne conducted at constant current, constant power, constant resistance or in accordance with a preselected load profile.

If any question about Torkel 840/860 problems, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com


Monday, November 16, 2015

Rolls-Royce WRC1021B Controller board on Brattvaag Crane successfully repaired and Tested by PT. Dynamics Circuit Indonesia. What if your cost saving machine has gone repair? Don't worry, Just contact us :

Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan...

Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com


The dc dielectric test sets are used to make proof tests and insulation tests on electrical power cables, motors, switchgear, insulators, transformers and capacitors. Both types of test are performed by applying controlled high voltages to the unit under test at or above insulation system operating level. Measuring the leakage current helps determined the unit under test's ability to withstand overvoltages such as lighting strikes and switching surges.

If any question about dc dielectric test sets problem, don't hesistate to contact us :

Kompleks Duta harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com


The DELTA2000 is a fully automatic 10kV insulation power factor test set designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery.

If any question about Megger DELTA2000 problem, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan
Jakarta Utara - 14460
Indonesia
Phone & Fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com
Website : www.dynamicscircuit.com


We specialize in test-instrument repair and PCB repair for various brand. All repairs are done In-house and we do not sub out. 

If any question, don't hesistate to contact us :

PT. Dynamics Circuit Indonesia
Kompleks Duta Harapan Indah Blok JJ/2
Kapuk Muara, Penjaringan...
Jakarta Utara - 14460
Phone & Fax : +62-21-6603014
Email : indoservice@dynamicscircuit.com
Website : http://www.dynamicscircuit.com